In a cleanroom where fan filter units or HEPA filters cover most of the ceiling, there is little room for recessed light fixtures. Teardrop lights solve this by mounting directly on the ceiling grid's T-bar, below and between the filters. Their narrow, tapered profile lets downward air divide and rejoin around the fixture with minimal turbulence underneath.
They are mainly used in unidirectional airflow areas and rooms with high filter coverage, typically ISO 5 and cleaner. Rooms with partial filter coverage, such as many ISO 7 and 8 rooms, more often use sealed flat LED panels set flush in the ceiling.
Features to look for:
- Sealed, gasketed housings with a smooth, wipeable surface.
- Materials and lenses that tolerate the disinfectants in use.
- Mounting that suits the grid profile and does not block filter faces.
- Wiring and maintenance access that, where possible, do not require opening the clean ceiling.
Cleanroom task lighting is commonly designed for around 500 lux or more at the work surface, with higher levels for inspection and detailed assembly. The process and the owner's standards set the final figure.
See cleanroom lighting: panels, teardrops and lux levels and the teardrop LED light.