LaboratoryEquipment.caCasework · Fume hoods · Cleanrooms Placeholder data
Resources

Guides to fume hoods, casework and cleanrooms

80 practical guides for lab managers, EHS officers, architects and researchers. Also see the glossary and materials.

Fume hoods

How a laboratory fume hood works

How a fume hood captures and removes contaminants, what each part does, and the conditions that decide whether it actually protects the user.

4 min read

Face velocity: what it measures and what it doesn't

What fume hood face velocity is, how to measure it properly, typical targets, and why a good reading does not prove that a hood contains.

4 min read

ASHRAE 110 containment testing explained

What the ANSI/ASHRAE 110 fume hood test involves, what AM, AI and AU results mean, and how to specify the test and read the report.

4 min read

CSA Z316.5 and fume hoods in Canada

What CSA Z316.5 covers, how it fits with provincial rules and other standards, and how to use it when specifying and testing fume hoods.

4 min read

Bypass, CAV and VAV fume hoods compared

How conventional, bypass and variable air volume fume hoods respond to sash movement, and what each means for safety, energy and building controls.

4 min read

High-performance low-flow hoods: when they pay off

How high-performance fume hoods contain at lower face velocity, where the energy savings are real, and when a standard hood is the better choice.

3 min read

Vertical, horizontal and combination sashes

How vertical, horizontal and combination fume hood sashes work, how each affects shielding and exhaust volume, and how to choose between them.

4 min read

Sash height and safe working habits

Practical fume hood habits for users and lab managers: sash position, where to work, what to keep out of the hood and how to respond to alarms.

4 min read

Baffles and slot adjustment

What fume hood baffles do, how slot settings change the airflow, when adjustment makes sense, and how to inspect and clean the plenum behind them.

4 min read

Why airfoil sills matter

How the airfoil sill at the front of a fume hood prevents reverse flow at the work surface, and what users and maintenance staff can do to keep it working.

4 min read

Choosing a fume hood liner

How to choose a fume hood liner by chemistry, heat and cleaning needs, comparing FRP, stainless steel, PVC and other common liner materials.

4 min read

Ductless filtered fume hoods: uses and limits

How ductless filtered fume hoods work, where they are a sensible choice, where they are not, and the filter monitoring they depend on.

4 min read

Walk-in fume hoods

When a floor-mounted walk-in fume hood is the right choice, and how to plan its sashes, floor, services, exhaust and safe use.

4 min read

Perchloric acid hoods and washdown systems

Why heated perchloric acid needs a dedicated washdown hood, how the hood, duct and fan are built, and how to operate and decommission one safely.

4 min read

Radioisotope fume hoods

How radioisotope fume hoods differ from standard hoods, from seamless stainless liners and shielding loads to filtered exhaust and CNSC licensing.

4 min read

Where to place fume hoods in a room

How to locate fume hoods away from doors, aisles and supply air, with the clearances, exit routes and nearby safety equipment to plan for.

5 min read

Cross drafts, diffusers and supply air

Why room air movement can defeat a fume hood, how diffusers, doors and people create cross drafts, and how to design for and check them.

4 min read

Exhaust ducts, fans and stacks

How fume hood exhaust systems are built: duct materials, fan location, dedicated versus manifolded fans, and stack height and discharge velocity.

4 min read

Airflow monitors and alarms

How fume hood airflow monitors work, the main sensor types, where to set alarms, and how to keep monitors calibrated and trusted by users.

4 min read

Fume hood energy use and how to cut it

Why fume hoods use so much energy in Canadian labs, and the practical ways to cut it: VAV, sash management, low-flow hoods and heat recovery.

4 min read

Commissioning and annual certification

What happens when a fume hood is commissioned and recertified each year: ASHRAE 110 test modes, face velocity checks, alarms, labels and records.

4 min read

Fume hood or biosafety cabinet?

How chemical fume hoods, biosafety cabinets and clean benches differ in what they protect, and how to choose for chemical, biological and mixed work.

4 min read

Base cabinets under fume hoods

How to choose the cabinets under a benchtop fume hood: general, flammable and corrosive storage, vacuum pump and knee-space bases, and how to vent them.

4 min read

Fume hood services and fixtures

Planning water, gases, vacuum, power and drains for a fume hood: which services to specify, where controls belong and what to keep out of the hood.

4 min read

How many fume hoods, and how wide?

How to work out how many fume hoods a lab needs and which widths to choose, from the work done at each hood to the exhaust the building can supply.

4 min read

Fume hood maintenance checklist

A practical fume hood maintenance checklist by frequency, showing what users, lab staff, facilities and certifiers should check and when.

4 min read

Common fume hood mistakes

The most common fume hood mistakes in planning, purchasing and daily use, with simple fixes that protect users and keep hoods working as designed.

4 min read

Hoods for distillation and tall apparatus

Choosing a hood for distillation columns, reactors and other tall setups: distillation hoods, walk-in hoods, sash options and safe rigging.

4 min read

Fume hood noise and how to keep it down

Where fume hood noise comes from, from airflow at the opening to fans, VAV valves and diffusers, and the design steps that keep labs quieter.

4 min read

Retrofit or replace an old fume hood?

How to assess an ageing fume hood and decide between repairs, upgrades such as VAV and airflow monitors, or full replacement.

4 min read

Casework and lab planning

Lab casework buying guide

How to specify and buy lab casework: construction material, worktops, configuration, hardware, standards, lead times and questions for suppliers.

4 min read

Steel, wood or phenolic casework?

Compare painted steel, wood and solid phenolic lab casework on moisture, chemicals, durability and repair, and see where each material fits best.

4 min read

When stainless steel casework is worth it

Where stainless steel lab casework earns its higher cost, how grades 304 and 316 differ, and its limits with chlorides, acids and cleaning products.

4 min read

SEFA 8 casework standards explained

What SEFA 8M, 8W and 8PH cover, what the casework tests check, what they leave out, and how to read a supplier's compliance claim.

4 min read

Standard lab bench heights, depths and widths

Typical lab bench heights, depths, cabinet widths, toe kicks and overhead clearances in metric and imperial, and when to depart from them.

4 min read

Epoxy resin vs phenolic resin worktops

How epoxy resin and phenolic resin lab worktops compare on chemicals, heat, weight, impact, sinks and edges, and the labs each one suits best.

4 min read

Choosing a lab worktop by chemical and heat exposure

Match a lab worktop to the chemicals, heat, moisture and cleaning it will see, with an exposure table and a simple method for testing samples.

4 min read

Fixed, mobile or adaptable casework

How fixed, mobile and adaptable lab casework compare on cost, flexibility, services and safety, and how to choose the right mix for your lab.

4 min read

Island benches and wall benches

When to use wall benches, peninsulas or freestanding islands in a lab, how services reach each one, and what each means for circulation and egress.

4 min read

Aisle widths and clearances

Typical lab aisle widths for single and back-to-back work and carts, plus clearances around hoods, showers, doors, equipment and sprinklers.

3 min read

Planning a lab layout step by step

A step-by-step method for planning a lab layout, from the work program and hazards to fixed elements, benches, services, storage and user review.

4 min read

Lab modules: planning on a grid

What a lab module is, how its width and depth are derived, and how planning on a repeating grid keeps structure, services and casework flexible.

4 min read

Lab sinks, cup sinks and drainage

How to choose and place lab sinks, cup sinks and faucets, and what to check about chemical-resistant drain lines and sewer discharge.

4 min read

Reagent shelving: what to store overhead

What belongs on lab reagent shelves and what does not, plus typical shelf depths, heights, lips and seismic restraint for shelving above benches.

4 min read

Wall cabinets and glass-door storage

When to choose glass-door or solid-door wall cabinets in a lab, typical sizes and mounting heights, and what should never be stored in them.

4 min read

Drawer configurations for lab storage

How to choose drawer heights, slides, locks and inserts for lab base cabinets, and how to balance drawers against door storage along a bench.

5 min read

Flammable liquid storage cabinets

What a flammable storage cabinet does, the construction details to check, where to place it, whether to vent it, and how codes limit quantities.

4 min read

Acid and corrosive storage cabinets

How to choose and place acid and base storage cabinets, which construction resists vapour attack, when to vent, and how to separate acids inside.

4 min read

Chemical segregation and compatible storage

How to sort lab chemicals into compatible storage groups, turn those groups into cabinets and shelves, and keep the system working after move-in.

4 min read

Emergency showers and eyewash stations

Where to put emergency showers and eyewashes, the ANSI Z358.1 flow, height and temperature figures, and how to plan water supply, drainage and testing.

4 min read

Ergonomics at the lab bench

How bench height, knee space, seating, reach and task design reduce strain at the lab bench, with practical layout choices for standing and seated work.

4 min read

Lab service fixtures and outlets

The water, gas, vacuum, purified water and electrical fixtures found on lab benches, how they are mounted, and the safety details to plan for.

4 min read

Balance tables and vibration control

What disturbs sensitive lab balances, how anti-vibration balance tables work, and where to place weighing stations for stable, repeatable readings.

4 min read

Planning a lab renovation

How to plan a lab renovation, from the program and existing-conditions survey to decommissioning, phasing, approvals and the schedule to move-in.

4 min read

Lead times, delivery and installation

What drives lead times for lab casework and fume hoods, how to prepare a site for delivery, the usual installation sequence and who does what.

4 min read

Budgeting for lab casework and hoods

The cost drivers behind lab casework, worktops and fume hoods, how hood choices affect building costs, and how to build a realistic furniture budget.

4 min read

Accessible and barrier-free lab work stations

How to design lab benches, sinks, hoods, safety equipment and circulation so people with disabilities can work safely and independently.

4 min read

Cleaning and caring for lab surfaces

Routine cleaning, disinfection and care for epoxy, phenolic and stainless worktops, casework finishes, sinks and hood interiors, and what to avoid.

4 min read

Biosafety cabinet classes and types

Class I, II and III biosafety cabinets and Class II types A1, A2, B1, B2 and C1 compared, with guidance on choosing, placing and certifying them.

5 min read

Clean benches and PCR workstations

How laminar flow clean benches and PCR workstations protect work from contamination, why they do not protect the user, and how to lay out a PCR lab.

4 min read

Cleanrooms

ISO 14644-1 cleanroom classes explained

What ISO 14644-1 cleanroom classes mean, how particle limits scale from ISO 5 to ISO 8, and how to choose a class without over-specifying.

4 min read

GMP cleanroom grades A to D

How GMP Annex 1 grades A, B, C and D compare with ISO classes, what each grade is used for, and what the grades mean for room design.

4 min read

Cleanroom windows: flush glazing done right

Why cleanroom windows sit flush on both faces of the wall, how sealed double-glazed units are built, and where windows earn their place in a suite.

4 min read

Cleanroom lighting: panels, teardrops and lux levels

How to choose cleanroom lighting: sealed flat panels or teardrop fixtures, typical light levels, ceiling coordination and room-side servicing.

4 min read

Fan filter units and ceiling coverage

How fan filter units work, how much of the ceiling they typically cover for each ISO class, and what to check on motors, filters, controls and noise.

4 min read

Cleanroom wall and ceiling systems

Modular panels, coated drywall, grid ceilings and walkable ceilings compared, with notes on panel cores, fire performance, joints and choosing a system.

4 min read

Cleanroom flooring and coving

Sheet vinyl, resin and static-control floors for cleanrooms, why integral coving matters, and how to prepare the slab so the floor lasts.

4 min read

Cleanroom doors and interlocks

Swing and hermetic sliding doors for cleanrooms, which way doors should open, how interlocks protect the pressure cascade, and how to keep egress safe.

4 min read

Pass-through chambers

Static, ventilated and decontamination pass-through chambers compared, with advice on interlocks, sizing, construction and safe transfer procedures.

4 min read

Air showers: when they help

How cleanroom air showers work, what they can and cannot remove, where they earn their space, and what to check on noise, interlocks and egress.

4 min read

Designing a gowning room

How to lay out a gowning room around the gowning sequence, with the cross-over bench, sink, garment storage and pressure in the right places.

4 min read

Pressure cascades and airlocks

How pressure cascades keep air flowing from clean to less clean rooms, typical differentials, and when to use cascade, bubble or sink airlocks.

4 min read

Softwall vs hardwall cleanrooms

Softwall, rigid-wall and modular hardwall cleanrooms compared on pressure control, cleanliness, mobility, regulatory fit and cost drivers.

3 min read

Cleanroom HVAC and air change rates

How cleanroom air systems work, typical air change ranges by ISO class, why recovery and heat load matter more than one number, and how to save energy.

4 min read

Cleanroom certification and monitoring

What a cleanroom certification visit tests, how often rooms are requalified, how routine monitoring fills the gaps, and how to choose a certifier.

4 min read

Cleanroom furniture and stainless steel

How to choose cleanroom tables, shelving, seating and storage, when 304 or 316 stainless is the right grade, and which finishes clean best.

4 min read

Pharmacy compounding cleanrooms

How sterile compounding suites are laid out under the NAPRA model standards and USP chapters, including room classes, pressures and design details.

4 min read

Cleanroom cleaning and disinfection

How cleanroom programs combine detergents, disinfectants and sporicides, which techniques work, typical frequencies, and designing rooms that clean well.

4 min read

Planning a cleanroom budget

What drives cleanroom capital and operating costs, where budgets usually go wrong, and how to build an estimate that holds up as the design develops.

4 min read

Sealing penetrations, outlets and utilities

How to plan, seal and test every pipe, cable, sprinkler and outlet that passes through a cleanroom envelope, so the room holds pressure and cleans well.

4 min read