Casework, fume hoods, safety storage and cleanroom products
Every product is modeled in 3D. Open one to rotate it, choose a width and finish, and add it to your cart or your lab plan.
Base cabinets
Floor-standing casework that carries the worktop: hinged-door, drawer, combination, sink and knee-space units in four widths.

Base cabinet, hinged doors
Adjustable shelf, full-overlay doors with 270° hinges. Leveling toe kick.

Base cabinet, 4 drawers
Full-extension drawers rated to 45 kg, graduated heights for glassware and consumables.

Base cabinet, drawer over doors
The workhorse of a lab run: one shallow drawer above a shelved cupboard.

Sink base with epoxy sink & faucet
Molded epoxy sink, gooseneck faucet with vacuum breaker, and open back for plumbing.

Knee space with modesty panel
Seated work position under a continuous worktop. Apron rail and removable back panel.
Wall & shelving
Wall-mounted cabinets, open reagent shelves and pegboards that keep glassware and reagents within reach and off the worktop.

Wall cabinet, glass doors
Framed tempered-glass doors and two adjustable shelves. Mounted 1450 mm above floor.

Wall cabinet, solid doors
Solid doors and two adjustable shelves. Mounted 1450 mm above floor.

Open reagent shelf
Wall-mounted shelf with lip rail so bottles stay put. Shown stocked for scale.

Epoxy pegboard drying rack
Epoxy resin board with removable pegs and a drip trough, mounted above a sink.
Fume hoods
Benchtop, high-performance, walk-in, ductless, perchloric acid and radioisotope hoods for every level of chemical containment.

Benchtop fume hood, bypass
Airfoil sill and bypass grille, 0.5 m/s face velocity at 460 mm sash. Supplied with vented base cabinets.

High-performance low-flow hood
Designed to contain at reduced face velocity when tested to ASHRAE 110. Combination sash cuts exhaust volume.

Walk-in fume hood
Floor-mounted for carts, reactors and tall apparatus. Two-tier vertical sash.

Ductless filtered fume hood
Carbon-filtered enclosure for low-volume, well-characterized chemistry where ducting is impractical. Includes mobile base.

Perchloric acid hood with washdown
Welded stainless 316 liner, integral washdown spray system and coved work surface with drain trough. Needs a dedicated exhaust.

Radioisotope fume hood
Seamless stainless liner and coved stainless work surface reinforced to carry lead shielding.
Safety storage
Tall storage and dedicated cabinets for flammable liquids and corrosives, kept apart as segregation rules require.

Tall storage cabinet
Split upper and lower doors, five adjustable shelves, keyed lock.

Flammable liquids cabinet, 45 gal
Double-wall steel, self-closing doors and a leak-proof sill, designed for flammable liquid storage under NFPA 30.

Corrosives cabinet, 30 gal
Polyethylene trays and epoxy-coated interior for acids and bases.
Tables & benches
Mobile tables, adaptable C-frame benches, island benches with reagent shelving and isolated balance tables.

Mobile lab table
Welded steel frame on locking casters, lower shelf, choice of worktop.

Adaptable C-frame bench
Height-adjustable C-frame with a suspended drawer unit and overhead shelf. Reconfigures without tools.

Island bench with reagent shelving
Double-sided island: base cabinets both faces, center service strip with power and gas, two reagent shelves.

Anti-vibration balance table
Granite slab isolated from the surrounding worktop on its own steel frame.
Safety & equipment
Biosafety cabinets, clean benches, PCR workstations and emergency showers that sit alongside casework.

Biosafety cabinet, Class II A2
HEPA-filtered supply and exhaust, sloped front, on stand with leveling feet.

Laminar flow clean bench, horizontal
HEPA-filtered horizontal airflow protects the work, not the user. For non-hazardous sterile preparation.

PCR workstation with UV
Clear enclosure with UV-C decontamination cycle and HEPA-filtered recirculation, supplied on a steel bench.

Emergency shower & eyewash
Combination unit with stay-open valves, designed around ANSI Z358.1.
Cleanroom
Flush windows, sealed LED lighting, fan filter units, doors, pass-throughs, air showers, gowning furniture and softwall enclosures.

Cleanroom flush window, double-glazed
Flush on both faces of the wall panel, sealed double glazing with no ledges to collect particles.

Cleanroom door with vision panel
Flush-faced door with gasketed frame and automatic drop seal. Double leaf for equipment access.

Pass-through chamber, interlocked
Stainless chamber through the wall with interlocked doors, so both sides can never be open at once.

Cleanroom LED flat panel, IP65
Gel-sealed LED panel, serviceable from the room side, sized to a standard ceiling grid.

Teardrop LED light
Mounts on the ceiling grid T-bar, so it never takes the place of a filter or panel.

Fan filter unit with HEPA
EC-motor fan and H14 HEPA filter in one ceiling module, room-side replaceable and speed controlled.

Air shower
HEPA-filtered high-velocity nozzles strip particles from garments before entry. Interlocked doors.

Cross-over gowning bench
Stainless bench that marks the clean/dirty line, with shoe storage below.

HEPA garment storage cabinet
Glass-front stainless cabinet with HEPA-filtered downflow keeps clean garments clean between uses.

Stainless cleanroom work table
Electropolished stainless frame and top with open, wipe-down construction and no hidden ledges.

Stainless scrub sink, hands-free
Deep stainless basin with knee- or sensor-operated water and a backsplash with no horizontal ledges.

Room pressure monitor
Wall-mounted differential pressure display with local alarm, flush with the panel.

Softwall cleanroom enclosure
Free-standing steel frame, anti-static vinyl curtains and ceiling FFUs. Moves when the lab does.