A cleanroom cleanliness rating under ISO 14644-1, from ISO 1 (cleanest) to ISO 9, based on the maximum allowed airborne particle concentration.

ISO 14644-1 classifies cleanrooms and clean zones by the number of airborne particles allowed per cubic metre of air at specified particle sizes. Each class step is a factor of ten. The classes used most often in labs, pharmacy and manufacturing are:

ISO classMax particles ≥0.5 µm per m³Nearest former FS 209E class
ISO 53,520Class 100
ISO 635,200Class 1,000
ISO 7352,000Class 10,000
ISO 83,520,000Class 100,000

The US Federal Standard 209E was cancelled in 2001, but its class names still appear in conversation and older documents.

A class means little without its occupancy state. ISO 14644-1 recognizes three: as-built (empty room), at-rest (equipment installed, no people) and operational (normal work under way). A room that meets ISO 7 at rest may not do so in operation.

Classification is confirmed by a particle count at a number of locations set by the room's area. Pharmaceutical work also uses the GMP grades A to D, which relate to ISO classes but add microbial limits.