LaboratoryEquipment.caCasework · Fume hoods · Cleanrooms Placeholder data
Teardrop LED light 3D model Drag to rotate · scroll to zoom
Cleanroom · CR-TD-1200

Teardrop LED light, 1200 mm

Mounts on the ceiling grid T-bar, so it never takes the place of a filter or panel.

Width
1,200 mm (47 in)
Depth
150 mm (6 in)
Height
80 mm (3 in)
Mounting
Ceiling-mounted
List price
$290
CAD, before tax · placeholder pricing

The 1200 mm model

CR-TD-1200 is the 1200 mm (47 in) wide version of the teardrop led light. It is 150 mm deep and 80 mm high, ceiling-mounted. It also comes in 1500 mm.

What it's for

In high-grade cleanrooms the ceiling is mostly filters. An ISO 5 zone with unidirectional flow may have nearly every grid opening filled with fan filter units, leaving no room for flat panel lights. A teardrop light solves this by hanging from the T-bar between filters instead of taking an opening. Its tapered profile lets the downward airstream close back together below the fixture, with less disturbance than a flat-bottomed light would cause.

Construction and features

  • An aluminum body with a smooth painted or anodized finish, and a sealed diffuser on the lower faces.
  • Sealed end caps and joints, so nothing collects inside and the whole fixture can be wiped.
  • Mounting clips matched to the grid's T-bar profile, holding the light tight to the bar without drilling.
  • A sealed cable entry through the grid, so the power feed does not open a path from the plenum into the room.

Sizes and options

Two lengths: 1200 mm (47¼ in) and 1500 mm (59 in). Choose the length that matches the spacing of the grid members it runs along, so each light spans cleanly from cross-tee to cross-tee. Lights can run end to end along a grid line for a continuous row. Confirm the T-bar profile, emergency battery versions, dimming and CCT before ordering, since a clip that does not suit the grid means site modification.

Where it fits

Teardrops belong in ceilings dense with filters: ISO 5 and ISO 6 zones in electronics and semiconductor cleanrooms, softwall enclosures with full filter coverage, and the high-coverage filter ceilings over critical process zones in larger cleanroom suites.

Planning notes

  • Lay out filters first, then add teardrops along T-bars to reach the lighting target. Light comes from lines rather than panels, so check uniformity across the work surface, not only the average.
  • Keep fixtures off the line directly above critical work points where possible. Airflow visualization during qualification shows whether a fixture's wake reaches the work.
  • Confirm the grid can carry the added load, especially a gel-seal grid already supporting heavy filter modules.
  • Plan how power reaches each fixture. On a walkable ceiling wiring can be serviced from above; otherwise decide room-side access before the ceiling closes.
  • Check clearances. The fixture hangs about 80 mm below the ceiling plane, which can matter over door heads and tall equipment in a 2.7 m (8 ft 10 in) room.
  • Do not mix teardrops into a lay-in ceiling simply for looks. Where grid openings are available and filter coverage is partial, flat panels give more light per fixture and are easier to service.

All sizes

CodeWidthDepth × heightFrom
CR-TD-12001,200 mm (47 in)150 × 80 mm$290
CR-TD-15001,500 mm (59 in)150 × 80 mm$340

Often specified with