The 900 mm model
PW-UV-0900 is the 900 mm (35½ in) wide version of the pcr workstation with uv. It is 650 mm deep and 1650 mm high, floor-standing. It also comes in 1200 mm.
What it's for
A PCR workstation gives a clean, enclosed space for setting up amplification reactions. PCR is sensitive enough that a trace of previously amplified DNA, carried in on gloves, pipettes or aerosols, can produce false positives. The workstation keeps reagents and reaction set-up away from that contamination, and its UV cycle damages stray nucleic acid on exposed surfaces between sessions.
It is not a biosafety cabinet and does not protect the user from infectious material. Samples that may contain live pathogens should be opened and inactivated in a biosafety cabinet first.
Construction and features
- A clear enclosure gives good visibility and keeps room air and passing traffic away from the work area.
- A UV-C decontamination cycle irradiates the inside surfaces and anything left inside, usually run on a timer before and after each session.
- HEPA-filtered recirculation passes the air inside the enclosure through a HEPA filter, reducing particles and aerosols that would otherwise settle on the work surface.
- The workstation comes on a steel bench, so it is ready to use without separate casework.
When comparing workstations, look for a UV lamp that switches off automatically when the front is opened, a cycle timer, a lamp-hour counter, and interior materials that tolerate both UV and decontamination wipes.
Sizes and options
Where it fits
PCR workstations are standard in the pre-amplification area of a molecular biology and PCR lab. A forensic science lab uses them for DNA work, where contamination control is critical, and a hospital clinical lab uses them for molecular diagnostic set-up.
Planning notes
- Workflow matters more than the cabinet. Set up reactions in a pre-PCR area, amplify elsewhere, and analyze products in a separate post-PCR area, with people and materials moving one way only; see clean benches and PCR workstations.
- Give each area its own pipettes, consumables and lab coats, stored in its own drawer cabinets.
- UV-C harms skin and eyes. Run the cycle only with the enclosure closed and never bypass a UV interlock.
- UV lamps lose output with use. Replace them on the manufacturer's schedule, not when they stop glowing.
- UV only reaches surfaces in its direct line. Wipe down surfaces and equipment as well, and do not rely on UV for shaded areas or the inside of pipettes.
- Keep the workstation away from doors and drafts so the enclosure does not fill with room air each time someone walks in.
All sizes
| Code | Width | Depth × height | From |
|---|---|---|---|
| PW-UV-0900 | 900 mm (35½ in) | 650 × 1650 mm | $4,900 |
| PW-UV-1200 | 1,200 mm (47 in) | 650 × 1650 mm | $5,800 |