A PVC liner is the usual answer when a fume hood will see heavy use with mineral acids. Acid digestions for metals analysis, which often combine nitric, hydrochloric and sometimes hydrofluoric acid, wear down fiberglass and stainless liners over time. Rigid PVC stands up to them.
How it is made
PVC liners are built from rigid polyvinyl chloride sheet. Panels are cut, formed and joined by plastic welding, which fuses the seams into a continuous interior with no metal fasteners exposed to the airstream. Baffles and fittings inside the hood are often PVC or polypropylene for the same reason. Polypropylene liners are a related option for some metal-free and trace analysis work.
In the planner, the PVC liner is the acid digestion option, offered alongside fiberglass and stainless.
Performance
Acids. PVC resists hydrochloric, sulfuric and nitric acid across a wide range of concentrations, and many hydrofluoric acid procedures. Check strong, hot oxidizing acids against the maker's resistance chart.
Heat. This is the key limit. PVC softens at temperatures well below those of a hot plate surface. Hot plates and digestion blocks need heat shields, spacers or a heat-resistant work surface, and open flames should not be used in the hood.
Solvents. Ketones such as acetone, chlorinated solvents and aromatic solvents can soften or dissolve PVC. A PVC hood should be reserved for acid work.
Fire. PVC is combustible and releases hydrogen chloride when it burns. Ask the supplier about its fire properties and confirm acceptance with your fire safety reviewer.
Impact. Rigid PVC is tough at room temperature and does not chip like epoxy.
Where it suits
- Acid digestions for metals in environmental testing labs
- Sample preparation in mining and geochemistry assay labs
- Plating, etching and other mineral acid processes
Where it does not
- Perchloric acid, which needs a welded stainless liner with washdown and a dedicated exhaust. See perchloric acid hoods.
- Solvent-heavy organic chemistry, where a fiberglass liner is the better fit
- High-heat work without shielding
- Radioisotope work, which calls for a seamless stainless steel liner
Exposure summary
| Exposure | PVC performance |
|---|---|
| Hydrochloric, nitric, sulfuric acid | Very good |
| Hydrofluoric acid | Good for many procedures |
| Organic solvents | Poor |
| Direct heat | Poor, needs shielding |
| Perchloric acid | Not suitable |
The exhaust behind an acid hood needs the same care. Corrosion-resistant ductwork and fans are covered in exhaust ducts, fans and stacks.
Care and inspection
- Rinse acid residues from the work surface and lower liner after each session.
- Clean with mild detergent and water. Never use solvent-based cleaners.
- Look for warping or discoloration near heat sources, and check welds for cracks.
- Keep heat shields in place and replace them if they are damaged.
For a full comparison of liner options, see choosing a fume hood liner.