The 1800 mm model
FH-WI-1800 is the 1800 mm (71 in) wide version of the walk-in fume hood. It is 1000 mm deep and 2700 mm high, floor-standing. It also comes in 2400 mm.
Price by option at 1800 mm
| Option | Choice | List price |
|---|---|---|
| Liner | Fiberglass liner | $21,500 |
| Liner | Stainless 316 liner | $23,720 |
| Liner | PVC liner (acid digestion) | $24,380 |
What it's for
A walk-in hood encloses equipment that will not fit on a bench: pilot-scale reactors, large distillation columns, rotary evaporators on carts, drums and frame-mounted apparatus left running for days. The name describes how equipment is loaded, not how people work. Staff roll or carry the setup in with the sash raised, then close the sash and work from outside.
Construction and features
The hood is floor-mounted, so its floor is at or close to room floor level and carts roll straight in. The two-tier vertical sash divides the front into an upper and a lower panel. During operation, only the panel at the level you need to reach is opened, which keeps the open area, and the exhaust volume, under control.
In good-quality walk-in hoods, look for:
- A chemical-resistant floor pan or a low front curb that contains spills.
- A support lattice or mounting points for clamping tall apparatus.
- Service valves and electrical controls on the outside, so utilities can be shut off without reaching in.
- Lighting that covers the full working height.
- An ANSI/ASHRAE 110 as-manufactured test report for the model.
Sizes and options
Where it fits
Walk-in hoods appear where scale-up happens: a kilo lab and pilot plant, an organic synthesis lab running large distillations, and a materials science lab with furnaces or large reaction setups that release fumes.
Planning notes
- A walk-in hood exhausts a large volume of air. Confirm exhaust and makeup air capacity early, and consider VAV control and sash management to keep it in check; see walk-in fume hoods.
- The floor must be level, sealed and strong enough for reactors and loaded carts. If the hood has a curb, plan a ramp.
- Nobody should be inside the hood while hazardous work is running. Write that into the lab's procedures and post it on the hood.
- Leave clear floor in front at least as deep as the largest cart, plus room to turn it.
- Check apparatus height against the sash opening and the inside of the hood before ordering; hoods for distillation and tall apparatus covers the setup details.
All sizes
| Code | Width | Depth × height | From |
|---|---|---|---|
| FH-WI-1800 | 1,800 mm (71 in) | 1000 × 2700 mm | $21,500 |
| FH-WI-2400 | 2,400 mm (94½ in) | 1000 × 2700 mm | $24,800 |




